Pole-mounted TMG Transformers


The pole-mounted hermetically sealed oil power transformers (TMGS series) rated for 16-100 kVA, voltage class 6-10/0.4 kV, are designed to power small facilities, such as oil rigs, gas stations, cell antennas, farms, separate buildings, cottage estates, and small settlements.

TMGS transformers comply with the following patents of the Interregional Distribution Grid Company of Center: No. 99905 of 31.08.2010, No. 101278 of 31.08.2010, No. 133982 of 30.04.2013, No. 146463 of 27.01.2014.

Патент СТП № 99905 Патент СТП № 101278 Патент СТП № 133982 Патент СТП № 146463

Advantages:

  • savings on substation construction; 
  • reduced electrical energy losses, since the installation site is near the consumer; 
  • protection from unauthorized access; 
  • ease of installation; 
  • resistance to climatic factors (dust, rain, humidity, etc.)

Basic specifications of pole-mounted hermetically sealed oil power transformers

Transformer type

Pole-mounted TMG (TMGS)

Capacity

16, 25, 32, 40, 63, 100 kVA

Vector group

D/Yn-11 ,Y/Yn-0,Y/Zn-11

Material of HV and LV windings

aluminum/copper

Rated HV

6 (10) kV ±2×2.5%

Rated LV

400 V

Nominal climatic category

U1, UKhL1 as per GOST 15150 and GOST 15543.1

Cooling

AN (natural)

Operating, transportation, and storage temperatures

-45 ... +40 °C for U1
-60 ... +40 °C for UKhL1

Service life

30 years

Warranty period

up to 5 years

Regulatory documents

Technical Requirements TU-3411-005-01354533-2015
GOST R 52719, GOST 11677, GOST 30830

Design features
The unique design of the tank and the special mounting system ensure reliable and rigid mounting of the transformer on the pole. The transformer specifications allow for simplified connection to a 6(10) kV grid without using the transformer protection switchgear. Telecontrol systems can be used for remote monitoring of the transformer condition. 
The distribution cabinets and metering devices are mounted either in the customer's premises or on a pole. 

Operating conditions
TMG pole-mounted transformers are designed to operate in the open air at a temperature from -45 to + 40 °C. The HV and LV leads are designed to withstand the most severe weather and climatic conditions (dust, rain, high humidity, etc.). 

Complete set
The basic configuration includes a float-type oil level indicator. Options: Mounting kit, metal casing for protection of leads, telemetric control relay.   

Specifications and dimensions of TMGS 6(10) kV transformers

Capacity, kVA

Voltage

Wiring and vector group

Impedance voltage, %

No-load current, %

Losses, W

Overall dimensions

Weight, kg

 

height

length

width

 

HV, kV

LV, V

no-load, W

short circuit, kW

H, mm

L, mm

W, mm

active part

oil

total

16

6; 10

400;

230

D/Un-11;

U/Un-0;

Y/Zn-11;

4.5

3.5

85

440

890

800

600

120

60

220

25

4.5

3.5

115

600

890

800

600

130

65

240

32

4.5

3.0

150

700

1010

880

610

180

96

340

40

4.5

3.0

155

880

1010

880

610

190

96

350

63

4.5

1.6

220

1280

1068

901

668

250

110

420

100

4.5

1.6

270

1970

1125

1130

550

280

125

500